Back to Search Start Over

Simultaneous quantification of 5-FU, 5-FUrd, 5-FdUrd, 5-FdUMP, dUMP and TMP in cultured cell models by LC-MS/MS.

Authors :
Carli D
Honorat M
Cohen S
Megherbi M
Vignal B
Dumontet C
Payen L
Guitton J
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2009 Oct 01; Vol. 877 (27), pp. 2937-44. Date of Electronic Publication: 2009 Jul 18.
Publication Year :
2009

Abstract

To specifically quantify several metabolites of 5-fluorouracil (5-FU) and two endogenous monophosphate nucleotides, we developed an original method based on a liquid chromatography-tandem mass spectrometry (LC-MS/MS). This assay allowed the determination of: (i) the intracellular production of 5-fluoro-2'-deoxyuridine-5'-monophosphate (5-FdUMP) from 5-FU or 5-fluoro-2'-deoxyuridine (5-FdUrd), (ii) the impact of 5-FdUMP concentration on the intracellular 2'-deoxyuridine-5'-monophosphate (dUMP)/thymidine-5'-monophosphate (TMP) ratio, and (iii) the secretion extent of 5-FdUMP and 5-FU from human cultured cells by ABC transporters. Under our experimental conditions, cells were incubated with 5-FU or 5-FUrd. Then, cellular proteins were precipitated by methanol. This procedure provided high extraction recovery. In addition, to measure 5-FU and 5-FdUMP secretion from cells, we carried out quantification of these molecules in culture medium. Media were either directly injected (5-FU) or underwent a solid phase extraction using Oasis Wax extraction cartridge (5-FdUMP). Separation of analytes was performed on a dC18 Atlantis 3.5microm, (100mmx2.1mm i.d) column with isocratic mode using ammonium formate buffer/methanol/water (5/5/90, v/v) as mobile phase. The run time did not exceed 6.2min. The analytes were ionized in an electrospray interface under negative ion mode. We validated the method over a range of 2.5-150ngmL(-1) according to the compounds. Intra- and inter-assay variability was lower than 10% over seven days. All compounds were stable in cells or in culture medium when samples were stored at -20 degrees C for at least two weeks, and after three freeze-thaw cycles. No matrix effect was observed in both media.

Details

Language :
English
ISSN :
1873-376X
Volume :
877
Issue :
27
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
19620028
Full Text :
https://doi.org/10.1016/j.jchromb.2009.07.004