Back to Search Start Over

Rapid measurement of corneal diameter in children: validation of a clinic-based digital photographic technique.

Authors :
Puvanachandra N
Lyons CJ
Source :
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus [J AAPOS] 2009 Jun; Vol. 13 (3), pp. 287-8.
Publication Year :
2009

Abstract

Measuring corneal diameter is often difficult in infants, but its importance in certain circumstances cannot be overstated. Most available techniques for obtaining corneal diameter measurement are threatening to the child: the gold standard measurement technique relies on calipers and a ruler and necessitates general anesthesia for most children under the age of 7 years. Consequently, this important element of the pediatric eye examination is often not performed in clinic. We describe and prospectively validate a digital photographic technique for measuring corneal diameter, which is easy to perform, quick, nonthreatening, and provides an accurate corneal diameter measurement.

Details

Language :
English
ISSN :
1528-3933
Volume :
13
Issue :
3
Database :
MEDLINE
Journal :
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
Publication Type :
Academic Journal
Accession number :
19541269
Full Text :
https://doi.org/10.1016/j.jaapos.2009.01.006