Back to Search Start Over

Comparison of mobile- and fixed-bearing cemented total knee arthroplasty.

Authors :
Silvestre Muñoz A
Almeida Herrero F
Lopez Lozano R
Argüelles Linares F
Source :
Acta orthopaedica Belgica [Acta Orthop Belg] 2008 Dec; Vol. 74 (6), pp. 801-8.
Publication Year :
2008

Abstract

Concern about polyethylene wear and related osteolysis after knee arthroplasty has developed in the last years. Mobile-bearing knee prostheses were designed in order to reduce the influence of this critical factor on long-term success of total knee replacement. We present a prospective study comparing clinical and radiological results with a mobile-bearing (Ceragyr) and a fixed-bearing knee prosthesis (posterior stabilized Hermes). Clinical results did not show any significant differences in Knee Society scores. We found better results in the mobile-bearing group for pain scores and subjective preference, but the difference did not reach statistical significance. Within the time limits of this study, radiological analysis showed no osteolysis in either group, but longer follow-up will be needed to confirm this.

Details

Language :
English
ISSN :
0001-6462
Volume :
74
Issue :
6
Database :
MEDLINE
Journal :
Acta orthopaedica Belgica
Publication Type :
Academic Journal
Accession number :
19205328