Covered Cheatham-Platinum stents for serial dilation of severe native aortic coarctation.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2009 Jul 01; Vol. 74 (1), pp. 117-23. - Publication Year :
- 2009
-
Abstract
- Objectives: To report on the early results of treatment of native coarctation of the aorta by implantation and serial dilations of covered stents.<br />Background: Transcatheter dilation of native coarctation of the aorta carries a risk of aneurysm or rupture. Covered stent implantation requires a large delivery system with the risk of vascular damage.<br />Methods: Covered stents on balloons of diameter sufficient to anchor the stent in the coarctation were implanted using the smallest delivery system possible. Dilation with larger diameter balloons was performed until the pressure gradient was <20 mm Hg and the stent was opposed to the aortic wall.<br />Results: Twenty-two patients with native coarctation underwent stent implantation. Coarctation diameter increased from 3.6 +/- 1.9 to 12.6 +/- 1.9 mm (P < 0.001). Peak pressure gradient decreased from 29.4 +/- 8.5 to 6.7 +/- 5.7 mm Hg (P < 0.001). Nine patients underwent further dilation on average 5 months later. Residual pressure gradient decreased from 12.3 +/- 5.8 to 2.1 +/- 2.9 mm Hg (P = 0.002). The stent achieved the diameter of the transverse arch in all cases. Complications included a small tear at further dilation treated with a second stent and a femoral pseudoaneurysm. At short-term follow-up of 18.5 months all patients are alive and well with no evidence of recoarctation or aneurysm.<br />Conclusions: These initial results show that serial dilation of covered Cheatham-Platinum stents is feasible, safe, and an effective percutaneous method for the treatment of native coarctation of the aorta. However, long-term follow up is required.<br /> (Copyright 2009 Wiley-Liss, Inc.)
- Subjects :
- Adolescent
Aortic Coarctation diagnostic imaging
Aortic Coarctation physiopathology
Aortography
Blood Pressure
Catheterization adverse effects
Child
Feasibility Studies
Female
Humans
Male
Polytetrafluoroethylene
Prosthesis Design
Severity of Illness Index
Time Factors
Treatment Outcome
Young Adult
Aortic Coarctation surgery
Catheterization instrumentation
Coated Materials, Biocompatible
Platinum
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 74
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 19180664
- Full Text :
- https://doi.org/10.1002/ccd.21923