Back to Search Start Over

Effects of audio compression in automatic detection of voice pathologies.

Authors :
Sáenz-Lechón N
Osma-Ruiz V
Godino-Llorente JI
Blanco-Velasco M
Cruz-Roldán F
Arias-Londoño JD
Source :
IEEE transactions on bio-medical engineering [IEEE Trans Biomed Eng] 2008 Dec; Vol. 55 (12), pp. 2831-5.
Publication Year :
2008

Abstract

This paper investigates the performance of an automatic system for voice pathology detection when the voice samples have been compressed in MP3 format and different binary rates (160, 96, 64, 48, 24, and 8 kb/s). The detectors employ cepstral and noise measurements, along with their derivatives, to characterize the voice signals. The classification is performed using Gaussian mixtures models and support vector machines. The results between the different proposed detectors are compared by means of detector error tradeoff (DET) and receiver operating characteristic (ROC) curves, concluding that there are no significant differences in the performance of the detector when the binary rates of the compressed data are above 64 kb/s. This has useful applications in telemedicine, reducing the storage space of voice recordings or transmitting them over narrow-band communications channels.

Details

Language :
English
ISSN :
1558-2531
Volume :
55
Issue :
12
Database :
MEDLINE
Journal :
IEEE transactions on bio-medical engineering
Publication Type :
Academic Journal
Accession number :
19126465
Full Text :
https://doi.org/10.1109/TBME.2008.923769