Back to Search
Start Over
Comparison of cemented vs uncemented acetabular component positioning using an imageless navigation system.
- Source :
-
The Journal of arthroplasty [J Arthroplasty] 2009 Dec; Vol. 24 (8), pp. 1170-3. Date of Electronic Publication: 2008 Dec 04. - Publication Year :
- 2009
-
Abstract
- Hip navigation was used as an assessment tool to compare ability to reproduce trial and definitive acetabular placement in total hip arthroplasty, using cemented and uncemented components. We demonstrated a significant difference in reproducibility between components. Of 20 uncemented cups, 4 (20%) deviated from the target inclination by 5 degrees or more compared to none of 21 in the cemented group (P = .048). Of the 20 uncemented cups, 7 (35%) deviated from the target version by 5 degrees or more compared to none of 21 in the cemented group (P = .003). This may explain higher rates of revision for dislocation with uncemented components. There was also a significant difference between the groups with regard to deviation from planned leg length (P < .001).
Details
- Language :
- English
- ISSN :
- 1532-8406
- Volume :
- 24
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- The Journal of arthroplasty
- Publication Type :
- Academic Journal
- Accession number :
- 19056209
- Full Text :
- https://doi.org/10.1016/j.arth.2008.09.018