Back to Search Start Over

ISCEV Standard for full-field clinical electroretinography (2008 update).

Authors :
Marmor MF
Fulton AB
Holder GE
Miyake Y
Brigell M
Bach M
Source :
Documenta ophthalmologica. Advances in ophthalmology [Doc Ophthalmol] 2009 Feb; Vol. 118 (1), pp. 69-77. Date of Electronic Publication: 2008 Nov 22.
Publication Year :
2009

Abstract

This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for clinical electroretinography (ERG). The parameters for flash stimulation and background adaptation have been tightened, and responses renamed to indicate the flash strength (in cd x s x m(-2)). The ISCEV Standard specifies five responses: (1) Dark-adapted 0.01 ERG (rod response); (2) Dark-adapted 3.0 ERG (combined rod-cone response); (3) Dark-adapted 3.0 oscillatory potentials; (4) Light-adapted 3.0 ERG (cone response); (5) Light-adapted 3.0 flicker (30 Hz flicker). An additional Dark-adapted 10.0 ERG or Dark-adapted 30.0 ERG response is recommended.

Details

Language :
English
ISSN :
1573-2622
Volume :
118
Issue :
1
Database :
MEDLINE
Journal :
Documenta ophthalmologica. Advances in ophthalmology
Publication Type :
Academic Journal
Accession number :
19030905
Full Text :
https://doi.org/10.1007/s10633-008-9155-4