Back to Search Start Over

Antibody-based detection tests for the diagnosis of Helicobacter pylori infection in children: a meta-analysis.

Authors :
Leal YA
Flores LL
García-Cortés LB
Cedillo-Rivera R
Torres J
Source :
PloS one [PLoS One] 2008; Vol. 3 (11), pp. e3751. Date of Electronic Publication: 2008 Nov 18.
Publication Year :
2008

Abstract

Background: Numerous serologic tests are available for the diagnosis of H. pylori infection in children. Common designs of antibody-based detection tests are ELISA and Western Blot (WB). For developing countries with limited laboratory resources and access, ELISA would be the preferred method because of its simplicity, lower cost and speed. Although in adults ELISA has proven to be highly accurate in diagnosing H. pylori infection; in children, it has shown variable accuracy.<br />Methods/findings: We conducted a systematic review and meta-analysis to assess the accuracy of antibody-based detection tests for the diagnosis of H. pylori infection in children. Selection criteria included participation of at least 30 children and the use of a gold standard for H. pylori diagnosis. In a comprehensive search we identified 68 studies. Subgroup analyses were carried out by technique, immunoglobulin class, and source of test (commercial and in-house). The results demonstrated: 1) WB tests showed high overall performance, sensitivity 91.3% (95% CI, 88.9-93.3), specificity 89% (95% CI, 85.7-91.9), LR+ 8.2 (95% CI, 5.1-13.3), LR- 0.06 (95% CI, 0.02-0.16), DOR 158.8 (95% CI, 57.8-435.8); 2) ELISA-IgG assays showed low sensitivity 79.2% (95% CI, 77.3-81.0) and high specificity (92.4%, 95% CI, 91.6-93.3); 3) ELISA commercial tests varied widely in performance (test for heterogeneity p<0.0001); and 4) In-house ELISA with whole-cell antigen tests showed the highest overall performance: sensitivity 94% (95% CI, 90.2-96.7), specificity 96.4% (95% CI, 94.2-97.9), LR+ 19.9 (95% CI, 7.9-49.8), LR- 0.08 (95% CI, 0.04-0.15) DOR 292.8 (95% CI, 101.8-841.7).<br />Conclusions/significance: WB test and in-house ELISA with whole-cell antigen tests are the most reliable tests for the diagnosis of H. pylori infection in children. Antigens obtained from local strains of the community could partially explain the good overall accuracy of the in-house ELISA. Because of its cost and technical demands, in-house ELISA might be more suitable for use in developing countries.

Details

Language :
English
ISSN :
1932-6203
Volume :
3
Issue :
11
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
19015732
Full Text :
https://doi.org/10.1371/journal.pone.0003751