Back to Search Start Over

Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes.

Authors :
Del Carmen Plancha-Mansanet M
Caballero-Calabuig E
Félix-Fontestad J
Reyes-Ojeda MD
Sopena-Novales P
Abreu-Sánchez P
Del Carmen Cano-Terol M
Sopena-Monforte R
Source :
Journal of nuclear medicine technology [J Nucl Med Technol] 2008 Dec; Vol. 36 (4), pp. 213-6. Date of Electronic Publication: 2008 Nov 13.
Publication Year :
2008

Abstract

Unlabelled: Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied.<br />Methods: (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared.<br />Results: The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h.<br />Conclusion: The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.

Details

Language :
English
ISSN :
0091-4916
Volume :
36
Issue :
4
Database :
MEDLINE
Journal :
Journal of nuclear medicine technology
Publication Type :
Academic Journal
Accession number :
19008289
Full Text :
https://doi.org/10.2967/jnmt.108.053488