Back to Search Start Over

Determination of PCBs in tetrachlorinated quinone using gas chromatography with electron capture detection.

Authors :
Bi XH
Xu XB
Zheng MH
Meng QY
Fu S
Source :
Talanta [Talanta] 2000 Jun 30; Vol. 52 (3), pp. 397-402.
Publication Year :
2000

Abstract

A simple, sensitive method for determining polychlorinated biphenyl (PCB) congeners in industrial product 2,3,5,6-tetrachloro-1,4-benzoquinone with GC/ECD detection has been developed. The method based on liquid-liquid extraction from tetrachlorinated quinone dissolved in N,N-dimethylformamide was found to be efficient for the determination of the levels of the investigated pollutants. A series of extraction and purification steps were designed for the sample pretreatment. The congener specific averages of recoveries were 82-96% for Aroclor 1242 and 1254 at a total spiking level of ca. 0.4 mug g(-1) sample. The reproducibilities of replicate determinations of different congeners were typically 5-19% except one with the average 13% R.S.D. (n=3). This method was applied to evaluate the background levels of PCBs in tetrachloro-1,4-benzoquinone, of which the corresponding PCB levels varied from 0.014 to 1.5 mug g(-1).

Details

Language :
English
ISSN :
1873-3573
Volume :
52
Issue :
3
Database :
MEDLINE
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
18967997
Full Text :
https://doi.org/10.1016/s0039-9140(00)00339-8