Back to Search
Start Over
A novel technique to prevent intra-operative pneumothorax in awake coronary artery bypass grafting: biomaterial neo-pleura.
- Source :
-
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2009 Jan; Vol. 35 (1), pp. 37-41. Date of Electronic Publication: 2008 Sep 27. - Publication Year :
- 2009
-
Abstract
- Objective: Pneumothorax caused by damaged pleura represents the biggest obstacle in awake coronary artery bypass grafting. In order to safely perform this surgery, a new technique was developed to close the damaged pleura.<br />Methods: A rub-and-spray method was employed using polyglycolic acid nonwoven fabric and fibrin glue. At first, some fibrinogen solution was rubbed on the edge of the pleural defect and then the PGA fabric was placed and the fibrinogen and thrombin solutions were sprayed. Using a thorax model, the burst pressure caused by positive pressure and the influence of negative pressure, moisture, time, continuous respiratory movement and pleural defect size were examined. In an animal experiment using pigs, the duration spent on repair was measured and any air leakage from the pleura was also identified.<br />Results: In the thorax model, the burst pressure was 355.9+/-55.8 mmHg with positive pressure and no significant difference in negative pressure, moisture, time and respiratory moment was identified. However, there was a significant difference in the defect size. In the animal model, repair was easily achieved regardless of the defect size or location and air leakage was not seen after repair. The average duration of repair was 21.0s.<br />Conclusions: The present method achieved a strong closure with sufficient durability. Since the fabric is soft and flexible and suturing is not required, moving and fragile pleura can be easily repaired regardless of the defect location and size. Once established, the present method may be used in other forms of awake thoracic surgery or reconstruction of the thorax.
- Subjects :
- Anesthesia, Epidural
Animals
Coronary Artery Bypass, Off-Pump methods
Disease Models, Animal
Fibrin Tissue Adhesive therapeutic use
Models, Anatomic
Pleura injuries
Pleura surgery
Pneumothorax etiology
Polyglycolic Acid
Prostheses and Implants
Sus scrofa
Tissue Adhesives therapeutic use
Biocompatible Materials therapeutic use
Coronary Artery Bypass, Off-Pump adverse effects
Intraoperative Complications prevention & control
Pneumothorax prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1873-734X
- Volume :
- 35
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 18824372
- Full Text :
- https://doi.org/10.1016/j.ejcts.2008.07.067