False-positive results of a rapid K39-based strip test and Chagas disease.

Authors :
Amato Neto V
Amato VS
Tuon FF
Gakiya E
de Marchi CR
de Souza RM
Furucho CR
Source :
International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases [Int J Infect Dis] 2009 Mar; Vol. 13 (2), pp. 182-5. Date of Electronic Publication: 2008 Sep 12.
Publication Year :
2009

Abstract

Background: The definitive diagnosis of visceral leishmaniasis (VL) requires invasive procedures with demonstration of amastigotes in tissue or promastigotes in culture. Unfortunately, these approaches require laboratory materials not available in poor countries where the disease is endemic. The correct diagnosis of VL is important, and made more difficult by the fact that several common tropical diseases such as malaria, disseminated tuberculosis, and enteric fever share the same clinical presentation. Serological tests have been developed to replace parasitological diagnosis in the field. A commercially available K39-based strip test for VL has been developed for this purpose. The endemic area of leishmaniasis in Brazil overlaps the endemic area of Chagas disease, a disease that can cause false-positive serological test results. The aim of this study was to evaluate the incidence of false-positive exams using a rapid test for VL in patients with Chagas disease.<br />Methods: A rapid test based on the recombinant K39 antigen of Leishmania was used in: (1) 30 patients with confirmed Chagas disease, (2) 30 patients with a serological diagnosis of Chagas disease by ELISA, indirect immunofluorescence, indirect hemagglutination, and chemiluminescence, (3) 30 healthy patients from a non-endemic area as the control group, (4) 30 patients with confirmed VL, and (5) 20 patients with proved cutaneous leishmaniasis.<br />Results: The sensitivity and specificity of the rapid strip test were 100% when compared with healthy volunteers and those with confirmed Chagas disease. One false-positive result occurred in the group with Chagas disease diagnosed by serological tests (specificity of 96%).<br />Conclusion: The rapid test based on recombinant K39 is a useful diagnostic assay, and a false-positive result rarely occurs in patients with a serological diagnosis of Chagas disease.

Details

Language :
English
ISSN :
1878-3511
Volume :
13
Issue :
2
Database :
MEDLINE
Journal :
International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases
Publication Type :
Academic Journal
Accession number :
18786847
Full Text :
https://doi.org/10.1016/j.ijid.2008.06.003