The new EANM paediatric dosage card: additional notes with respect to F-18.

Authors :
Lassmann M
Biassoni L
Monsieurs M
Franzius C
Source :
European journal of nuclear medicine and molecular imaging [Eur J Nucl Med Mol Imaging] 2008 Sep; Vol. 35 (9), pp. 1666-8. Date of Electronic Publication: 2008 Jun 24.
Publication Year :
2008

Abstract

Introduction: The previously published European Association of Nuclear Medicine (EANM) paediatric dosage card recommends 70 MBq F-18 or F-18 Fluoro-2-Deoxyglucose (F-18-FDG) as the "minimum recommended activity".<br />Discussion: Two recent publications demonstrate that when utilising F-18-labelled radiopharmaceuticals the administration of lower activities for small children is possible without losing image quality.<br />Conclusion: In the light of these findings the EANM dosimetry and paediatrics committee have decided to reduce the value for the "minimum recommended activity" for both F-18 and F-18-FDG to 26 MBq for 2D- and 14 MBq for 3D-acquisitions.

Details

Language :
English
ISSN :
1619-7070
Volume :
35
Issue :
9
Database :
MEDLINE
Journal :
European journal of nuclear medicine and molecular imaging
Publication Type :
Academic Journal
Accession number :
18574583
Full Text :
https://doi.org/10.1007/s00259-008-0799-9