Back to Search Start Over

Effective treatment of early Barrett's neoplasia with stepwise circumferential and focal ablation using the HALO system.

Authors :
Gondrie JJ
Pouw RE
Sondermeijer CM
Peters FP
Curvers WL
Rosmolen WD
Ten Kate F
Fockens P
Bergman JJ
Source :
Endoscopy [Endoscopy] 2008 May; Vol. 40 (5), pp. 370-9.
Publication Year :
2008

Abstract

Study Aims: The aim of the current study was to evaluate the efficacy and safety of stepwise circumferential and focal ablation using the HALO system for Barrett's esophagus containing flat, high-grade dysplasia (HGD) or residual dysplasia after endoscopic resection for HGD or intramucosal cancer (IMC).<br />Methods: Visible abnormalities were removed with endoscopic resection prior to ablation. Persistence of dysplasia and absence of IMC were confirmed with biopsy after endoscopic resection. A balloon-based electrode was used for primary circumferential ablation and an endoscope-mounted electrode was used for secondary focal ablation.<br />Results: Twelve patients (nine men; median age 70 years) were treated (median Barrett's length 7 cm). Visible abnormalities were removed by endoscopic resection in seven patients. The worst pathological grade of residual Barrett's esophagus after resection and prior to ablation was low-grade dysplasia (LGD) (n = 1) and HGD (n = 11). Patients underwent a median of one circumferential and two focal ablation sessions. Complete remission of dysplasia was achieved in 12/12 patients (100%). Complete endoscopic and histological removal of Barrett's esophagus was achieved in 12/12 patients (100%). There were no ablation-related stenoses, and no subsquamous Barrett's esophagus was observed in 363 biopsies obtained from post-ablation neo-squamous mucosa. Protocolized cleaning of the ablation zone and electrode in between ablations resulted in superior regression of Barrett's esophagus compared with previous studies. During a median follow-up of 14 months no recurrence of dysplasia or Barrett's esophagus was observed.<br />Conclusions: Stepwise circumferential and focal ablation for Barrett's esophagus with flat HGD or for Barrett's with residual dysplasia after endoscopic resection for HGD/IMC is a safe and effective treatment modality. Its success rate and safety profile compare favorably with alternatives such as esophagectomy, widespread endoscopic resection or photodynamic therapy.

Details

Language :
English
ISSN :
1438-8812
Volume :
40
Issue :
5
Database :
MEDLINE
Journal :
Endoscopy
Publication Type :
Academic Journal
Accession number :
18494132
Full Text :
https://doi.org/10.1055/s-2007-995589