Back to Search
Start Over
Whole-body biodistribution and radiation dosimetry in monkeys and humans of the phosphodiesterase 4 radioligand [(11)C](R)-rolipram: comparison of two-dimensional planar, bisected and quadrisected image analyses.
- Source :
-
Nuclear medicine and biology [Nucl Med Biol] 2008 May; Vol. 35 (4), pp. 493-500. - Publication Year :
- 2008
-
Abstract
- Introduction: [(11)C](R)-Rolipram is a selective radioligand for positron emission tomography (PET) imaging of phosphodiesterase 4, an enzyme that metabolizes 3',5'-cyclic adenosine monophosphate. The aim of this study was to estimate the human radiation absorbed dose of the radioligand based on its biodistribution in both monkeys and humans.<br />Methods: Whole-body PET images were acquired for 2 h after injecting [(11)C](R)-rolipram in eight healthy humans and three monkeys. The simple method of using a single two-dimensional (2D) planar image was compared to more time-consuming methods that used two (bisected) or four (quadrisected) tomographic images in the anteroposterior direction.<br />Results: Effective dose was 4.8 microGy/MBq based on 2D planar images. The effective dose was only slightly lower by 1% and 5% using the bisected and quadrisected images, respectively. Nevertheless, the two tomographic methods may have more accurately estimated the exposure of some organs (e.g., kidneys) that are asymmetrically located in the body or have radioactivity that appears to overlap on 2D planar images. Monkeys had a different biodistribution pattern compared to humans (e.g., greater urinary excretion) such that their data overestimated the effective dose in humans by 40%.<br />Conclusions: The effective dose of [(11)C](R)-rolipram was modest and comparable to that of other (11)C-labeled radioligands. The simple and far less time-consuming 2D planar method provided accurate and somewhat more conservative estimates of effective dose than the two tomographic methods. Although monkeys are commonly used to estimate human radiation exposures, their data gave a considerable overestimation for this radioligand.
- Subjects :
- Animals
Cyclic Nucleotide Phosphodiesterases, Type 4 analysis
Haplorhini
Humans
Metabolic Clearance Rate
Phosphodiesterase 4 Inhibitors
Radiopharmaceuticals metabolism
Tissue Distribution
Whole Body Imaging
Whole-Body Counting
Carbon Radioisotopes metabolism
Positron-Emission Tomography methods
Radiation Dosage
Rolipram metabolism
Subjects
Details
- Language :
- English
- ISSN :
- 0969-8051
- Volume :
- 35
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Nuclear medicine and biology
- Publication Type :
- Academic Journal
- Accession number :
- 18482687
- Full Text :
- https://doi.org/10.1016/j.nucmedbio.2008.02.004