Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings: the effect on biological activity and microbial flora.
- Source :
-
Environmental research [Environ Res] 2008 Jul; Vol. 107 (3), pp. 291-8. Date of Electronic Publication: 2008 May 06. - Publication Year :
- 2008
-
Abstract
- Many building-related health problems coincide with moisture damage and mold growth within a building. Their elimination is assumed to improve indoor air quality. The aim of this study was to follow the success of remediation in two individual buildings by analyzing the microbial flora and immunotoxicological activity of filter samples. We compare results from samples collected from indoor air in the moisture-damaged buildings before and after renovation and results from matched reference buildings and outdoor air. The microbial characteristics of the samples were studied by analyzing ergosterol content and determining the composition of fungal flora with quantitative polymerase chain reaction (QPCR). In addition, the concentrations of particles were monitored with optical particle counter (OPC). The immunotoxicological activity of collected particle samples was tested by exposing mouse macrophages (RAW264.7) for 24 h to particle suspension extracted from the filters, and measuring the viability of the exposed cells (MTT-test) and production of inflammatory mediators (nitric oxide, IL-6 and TNF*) in cell culture medium by enzyme-linked immunoassay (ELISA). The results show that for Location 1 the renovation decreased the immunotoxicological activity of the particles collected from damaged building, whereas no difference was detected in the corresponding samples collected from the reference building. Interestingly, only slight differences were seen in the concentration of fungi. In the Location 2, a decrease was seen in the concentration of fungi after the renovation, whereas no effect on the immunotoxicological responses was detected. In this case, the immunotoxicological responses to the indoor air samples were almost identical to those caused by the samples from outdoor air. This indicates that the effects of remediation on the indoor air quality may not necessarily be readily measurable either with microbial or toxicological parameters. This may be associated with different spectrum of harmful agents in different mold and moisture-damaged buildings.
- Subjects :
- Aerosols
Air Pollution, Indoor adverse effects
Animals
Cell Line
Cell Survival drug effects
Environmental Monitoring
Ergosterol analysis
Fungi growth & development
Fungi isolation & purification
Interleukin-6 analysis
Macrophages drug effects
Macrophages immunology
Mice
Nitric Oxide analysis
Particulate Matter toxicity
Streptomycetaceae growth & development
Streptomycetaceae isolation & purification
Tumor Necrosis Factor-alpha analysis
Air Microbiology standards
Air Pollution, Indoor analysis
Building Codes
Construction Materials microbiology
Facility Design and Construction methods
Facility Design and Construction standards
Particulate Matter analysis
Subjects
Details
- Language :
- English
- ISSN :
- 1096-0953
- Volume :
- 107
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Environmental research
- Publication Type :
- Academic Journal
- Accession number :
- 18462714
- Full Text :