Back to Search Start Over

[2D-fluoroscopic navigated screw osteosynthesis of acetabular fractures: A preliminary report].

Authors :
Gras F
Marintschev I
Mendler F
Wilharm A
Mückley T
Hofmann GO
Source :
Zeitschrift fur Orthopadie und Unfallchirurgie [Z Orthop Unfall] 2008 Mar-Apr; Vol. 146 (2), pp. 231-9.
Publication Year :
2008

Abstract

Introduction: The current gold standard for operatively treated acetabular fractures is open reduction and internal fixation. In this study we report the early results of percutaneous screw osteosynthesis of acetabular fractures in 14 cases, using a computer navigation system to reduce screw misplacement, approach associated risks and radiation exposure.<br />Results: All 36 acetabular screws were placed correctly without any perioperative complication. The mean operation time per screw was 54 min, the mean fluoroscopic time per screw was 87 s. In the follow-up examinations (current rate: 71 %, mean follow-up: 13.1 +/- 1.8 months) no fixation failure or development of post-traumatic osteoarthritis was seen. One wound infection occured.<br />Conclusion: Our first experience with this novel approach is promising and serious advances of fluoroscopic navigated percutaneous screw osteosynthesis of well selected acetabular fractures can be expected.

Details

Language :
German
ISSN :
1864-6697
Volume :
146
Issue :
2
Database :
MEDLINE
Journal :
Zeitschrift fur Orthopadie und Unfallchirurgie
Publication Type :
Academic Journal
Accession number :
18404588
Full Text :