Reversed-phase high-performance liquid chromatographic approach to determine total lymphocyte concentrations of 6-thioguanine, methylmercaptopurine and methylthioguanine in humans.
- Source :
-
Journal of chromatography [J Chromatogr] 1991 Nov 15; Vol. 571 (1-2), pp. 149-56. - Publication Year :
- 1991
-
Abstract
- A reversed-phase high-performance liquid chromatographic (HPLC) procedure was developed to quantify intracellular lymphocyte 6-thioguanine, methylmercaptopurine and methylthioguanine. The free base of each metabolite was obtained by acid hydrolysis, which allowed for a total determination of thiopurine metabolites. 6-Thioguanine was analyzed on an octadecylsilane column using acetonitrile-10 mM sodium phosphate (11:89), pH 7, containing 0.06% tetrabutylammonium chloride. 6-Thioguanine was oxidized with potassium permanganate, and fluorescence was measured at 330 nm excitation and 410 nm emission. Methylmercaptopurine and methylthioguanine were separated on a cyanopropylsilane column using methanol-40 mM sodium phosphate (22:78), pH 2.7, and detected by ultraviolet absorbance at 314 and 290 nm, respectively.
Details
- Language :
- English
- Volume :
- 571
- Issue :
- 1-2
- Database :
- MEDLINE
- Journal :
- Journal of chromatography
- Publication Type :
- Academic Journal
- Accession number :
- 1810943
- Full Text :
- https://doi.org/10.1016/0378-4347(91)80441-e