Back to Search Start Over

Implementing a record-oriented clinical lab interface using HL7 version 2.1 at Indiana University Hospital.

Authors :
Shafarman MJ
Meeks-Johnson J
Jones T
McCoy J
van Valkenburg T
Source :
Proceedings. Symposium on Computer Applications in Medical Care [Proc Annu Symp Comput Appl Med Care] 1991, pp. 511-5.
Publication Year :
1991

Abstract

At the Indiana University Hospital (IUH) site on the Indianapolis campus, HL7 version 2.1 is being implemented via a TCP/IP LAN, (using the "Minimal" Lower Layer Protocol). HL7 is currently being used to convey record-oriented lab results from the local clinical laboratory system to a clinical database system via an intelligent router, which also provides store and forward capabilities. The database application displays the lab results in a variety of configurable formats to clinical users.

Details

Language :
English
ISSN :
0195-4210
Database :
MEDLINE
Journal :
Proceedings. Symposium on Computer Applications in Medical Care
Publication Type :
Academic Journal
Accession number :
1807653