First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices.

Authors :
Lee KL
Lau CP
Tse HF
Echt DS
Heaven D
Smith W
Hood M
Source :
Journal of the American College of Cardiology [J Am Coll Cardiol] 2007 Aug 28; Vol. 50 (9), pp. 877-83. Date of Electronic Publication: 2007 Aug 13.
Publication Year :
2007

Abstract

Objectives: The purpose of this study was to evaluate the feasibility and safety of a novel technology that uses energy transfer from an ultrasound transmitter to achieve cardiac stimulation without the use of a pacing lead in humans.<br />Background: To overcome the limitations of pacemaker leads, a new technology enabling stimulation without the use of a lead is desirable.<br />Methods: A steerable bipolar electrophysiology catheter incorporating a receiver electrode into the tip and circuitry to convert ultrasound energy to electrical energy was inserted transvenously into the heart. An ultrasound transmitting transducer was placed on the chest wall with ultrasound gel. Ultrasound energy was amplitude-adjusted and transmitted at 313 to 385 kHz. The output waveform of the receiver electrode was monitored while the transmitter was moved on the chest wall to target the receiver. The ultrasound transmission amplitude was limited to a mechanical index of 1.9, the maximum allowed for ultrasound imaging systems. Ultrasound-mediated pacing with minimum voltage but consistent capture was obtained for 12 s.<br />Results: Twenty-four patients (48 +/- 12 years) were tested during or after completion of clinical electrophysiology procedures. A total of 80 pacing sites were tested (mean 3.3 sites/patient): 12 right atrial, 35 right ventricular, and 33 left ventricular (31 endocardial) sites. The transmit-to-receive distance was 11.3 +/- 3.2 cm (range 5.3 to 22.5 cm). Ultrasound-mediated pacing was achieved at all 80 test sites, with consistent capture at 77 sites. The mechanical index during pacing was 0.5 +/- 0.3 (range 0.1 to 1.5). The mean ultrasound-mediated capture threshold was 1.01 +/- 0.64 V. There was no adverse event related to ultrasound pacing. No patient experienced discomfort during pacing.<br />Conclusions: The feasibility and safety of pacing usng ultrasound energy has been shown acutely.

Details

Language :
English
ISSN :
1558-3597
Volume :
50
Issue :
9
Database :
MEDLINE
Journal :
Journal of the American College of Cardiology
Publication Type :
Academic Journal
Accession number :
17719475
Full Text :
https://doi.org/10.1016/j.jacc.2007.04.081