Rectal erosion of synthetic mesh used in posterior colporrhaphy requiring surgical removal.

Authors :
Hurtado EA
Bailey HR
Reeves KO
Source :
International urogynecology journal and pelvic floor dysfunction [Int Urogynecol J Pelvic Floor Dysfunct] 2007 Dec; Vol. 18 (12), pp. 1499-501. Date of Electronic Publication: 2007 Jun 16.
Publication Year :
2007

Abstract

Treatment of pelvic organ prolapse with transvaginally placed synthetic mesh has recently increased. Several reports of complications have surfaced raising the overall question of safety regarding its use for vaginal prolapse repair. This case report describes a rectal erosion and dyspareunia that resulted from mesh placed into the posterior vaginal wall. A 47-year-old woman underwent a laparoscopic supracervical hysterectomy and a posterior repair with polypropylene mesh resulting in a rectal erosion. Despite removal of all of the mesh that could be excised rectally resulting in a healed rectal mucosa, the patient had persistent dyspareunia and pain requiring complete removal of the mesh using a vaginal approach. After surgery, the patient had resolution of all her symptoms. Further studies of transvaginally placed synthetic mesh need to be performed to determine its safety and efficacy.

Details

Language :
English
Volume :
18
Issue :
12
Database :
MEDLINE
Journal :
International urogynecology journal and pelvic floor dysfunction
Publication Type :
Academic Journal
Accession number :
17639344
Full Text :
https://doi.org/10.1007/s00192-007-0403-z