Back to Search
Start Over
Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome.
- Source :
-
Journal of the American College of Cardiology [J Am Coll Cardiol] 2007 Jul 03; Vol. 50 (1), pp. 69-76. Date of Electronic Publication: 2007 Jun 06. - Publication Year :
- 2007
-
Abstract
- Objectives: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California).<br />Background: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis.<br />Methods: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support.<br />Results: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%.<br />Conclusions: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
- Subjects :
- Age Factors
Aged
Aged, 80 and over
Aortic Valve Stenosis diagnosis
Aortic Valve Stenosis mortality
Cardiac Catheterization
Female
Follow-Up Studies
Humans
Male
Prospective Studies
Prosthesis Design
Risk Assessment
Severity of Illness Index
Single-Blind Method
Survival Rate
Treatment Outcome
Aortic Valve Stenosis therapy
Bioprosthesis
Heart Valve Prosthesis Implantation methods
Heart Valve Prosthesis Implantation mortality
Subjects
Details
- Language :
- English
- ISSN :
- 1558-3597
- Volume :
- 50
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of the American College of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 17601548
- Full Text :
- https://doi.org/10.1016/j.jacc.2007.04.047