First ISNS Reference Preparation for Neonatal Screening for thyrotropin, phenylalanine and 17alpha-hydroxyprogesterone in blood spots.
- Source :
-
Journal of inherited metabolic disease [J Inherit Metab Dis] 2007 Aug; Vol. 30 (4), pp. 609. Date of Electronic Publication: 2007 Jun 14. - Publication Year :
- 2007
-
Abstract
- Background: Neonatal screening for congenital disorders like phenylketonuria (PKU), congenital hypothyroidism (CH) and congenital adrenal hyperplasia (CAH) is generally performed in dried blood spots on filter paper. The analytes of interest for testing for PKU, CH and CAH are phenylalanine, thyrotropin (TSH) and 17alpha-hydroxyprogesterone (17OHP), respectively. The International Society for Neonatal Screening (ISNS) decided to prepare a combined reference preparation for the three analytes on filter paper Schleicher & Schuell #903, Whatman BFC180 and Toyo Roshi 545. This 'First ISNS Reference Preparation for Neonatal Screening for TSH, phenylalanine and 17OHP in blood spots' (1st ISNS-RPNS) has been prepared by the RIVM (Bilthoven).<br />Method: The number of filter paper cards prepared, each with two sets of six blood spot calibrators, was 480, 42 and 69 for Schleicher & Schuell #903, Whatman BFC180 and Toyo Roshi 545, respectively. The volume of blood dispensed was 50 microl. The range of concentrations for TSH was 1-121 mIU/L blood, for phenylalanine 65-865 micromol/L blood and for 17OHP 2.2-302 nmol/L blood.<br />Results: The linearity of the blood spot calibrators and the homogeneity of the batch (only tested for Schleicher & Schuell) were good. The differences between the three filter papers were small: i.e. the potency of the ISNS-RPNS on Whatman and Toyo Roshi in terms of Schleicher & Schuell was between 0.98 and 1.09 for the three analytes.<br />Conclusion: The 1st ISNS-RPNS for TSH, phenylalanine and 17OHP can be said to be suitable as formal reference preparation and as a source for (re)calibrating kit calibrators.
- Subjects :
- Blood Specimen Collection
Calibration
Equipment Design
Humans
Infant, Newborn
Paper
Quality Control
Regression Analysis
Reproducibility of Results
17-alpha-Hydroxyprogesterone blood
Blood Chemical Analysis standards
Neonatal Screening instrumentation
Neonatal Screening methods
Neonatal Screening standards
Phenylalanine blood
Phenylketonurias blood
Thyrotropin blood
Subjects
Details
- Language :
- English
- ISSN :
- 1573-2665
- Volume :
- 30
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of inherited metabolic disease
- Publication Type :
- Academic Journal
- Accession number :
- 17574536
- Full Text :
- https://doi.org/10.1007/s10545-007-0622-y