Back to Search Start Over

Improved survival associated with prophylactic implantable defibrillators in elderly patients with prior myocardial infarction and depressed ventricular function: a MADIT-II substudy.

Authors :
Huang DT
Sesselberg HW
McNitt S
Noyes K
Andrews ML
Hall WJ
Dick A
Daubert JP
Zareba W
Moss AJ
Source :
Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2007 Aug; Vol. 18 (8), pp. 833-8. Date of Electronic Publication: 2007 May 30.
Publication Year :
2007

Abstract

Introduction: We aim to evaluate the mortality benefit from defibrillator therapy in eligible elderly patients. Effective primary prevention of sudden cardiac death with implantable cardioverter defibrillators is well demonstrated in patients with coronary disease and depressed ventricular function.<br />Methods and Results: Among 1,232 patients enrolled with prior infarct and left ventricular ejection fraction < or = 0.30, 204 were > or = 75 years old. Of these 204 patients, 121 underwent defibrillator implant. Relative to the younger patients, those > or = 75 years had a higher incidence of atrial fibrillation, elevated blood urea nitrogen (BUN), widened QRS, and lower use of beta-blockers and HMG-CoA reductase inhibitors. Relevant clinical covariates were similar in elderly patients randomized to conventional and defibrillator therapy. The hazard ratio for the mortality risk in patients > or = 75 years assigned to defibrillator implant compared with those in conventional therapy was 0.56 (95 confidence interval 0.29-1.08; P = 0.08) after a mean follow-up of 17.2 months. Comparatively, the hazard ratio in patients < 75 years assigned to defibrillator implant was 0.63 (0.45-0.88; P = 0.01) after 20.8 months. Elderly patients had similar reductions in quality of life (QoL) regardless of treatment randomization. Scores through Health Utilities Index Mark III (HUI) Questionnaire changes from baseline to 1 year were -0.22 for patients with conventional therapy versus -0.20 for patients with ICD, and -0.36 versus -0.27 at 2 years, respectively (P = NS).<br />Conclusion: The implantable defibrillator is associated with an equivalent reduction of mortality in elderly and younger patients, with no compromise in the QoL in the older age subjects.

Details

Language :
English
ISSN :
1540-8167
Volume :
18
Issue :
8
Database :
MEDLINE
Journal :
Journal of cardiovascular electrophysiology
Publication Type :
Academic Journal
Accession number :
17537209
Full Text :
https://doi.org/10.1111/j.1540-8167.2007.00857.x