Measurement of spinal bone mineral density on a Hologic Discovery DXA scanner with and without leg elevation.
- Source :
-
Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry [J Clin Densitom] 2007 Apr-Jun; Vol. 10 (2), pp. 170-3. Date of Electronic Publication: 2007 Mar 26. - Publication Year :
- 2007
-
Abstract
- Although it is generally recommended that patients keep their hips flexed by 90 degrees during the measurement of spinal bone mineral density (BMD), there is no uniform agreement among the manufacturers of dual-energy X-ray absorptiometry (DXA) scanners regarding the positioning of legs while scanning the spine. We measured spinal BMD in 54 postmenopausal women, from L1 to L4 in posterior-anterior projection, using a Hologic Discovery scanner, first with their legs elevated as recommended by the manufacturer and then with their legs flat on the scanning table. Differences of bone mineral content (BMC), area of the region of interest (ROI), BMD, and T-score of the total spine between the 2 scans were compared. The mean (SD) age of the women was 54.3 yr (15 yr). Between the 2 scans, BMC, area of the ROI, BMD, and T-scores showed high correlations (r=0.98, 0.94, 0.99, and 0.99, respectively). BMC and the area of the ROI changed significantly between the 2 scans, but the changes of BMD and T-scores were not significant. The percentage changes of BMC and the area of the ROI were similar (2.6% and 2.4%, respectively), whereas T-scores showed no change and change of BMD was only 0.6%. The absolute difference in BMD between the 2 scans was only 0.005 (p=0.09). When spinal BMD was measured with their legs elevated, 31 women were found to have osteoporosis and further 13 were found to have osteopenia. When spinal BMD was measured with their legs flat, 32 women were found to have osteoporosis and further 12 were found to have osteopenia. In conclusion, no clinically or statistically significant difference in the total spinal BMD was found when the BMD in a group of women was measured on a Hologic Discovery DXA scanner with their legs positioned flat.
- Subjects :
- Equipment Design
Female
Humans
Leg
Middle Aged
Osteoporosis, Postmenopausal epidemiology
Osteoporosis, Postmenopausal metabolism
Reproducibility of Results
Absorptiometry, Photon instrumentation
Bone Density physiology
Lumbar Vertebrae diagnostic imaging
Osteoporosis, Postmenopausal diagnostic imaging
Posture
Subjects
Details
- Language :
- English
- ISSN :
- 1094-6950
- Volume :
- 10
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry
- Publication Type :
- Academic Journal
- Accession number :
- 17485034
- Full Text :
- https://doi.org/10.1016/j.jocd.2007.01.007