Back to Search Start Over

Allergy to technetium-labelled nanocolloidal albumin for sentinel node identification.

Authors :
Chicken DW
Mansouri R
Ell PJ
Keshtgar MR
Source :
Annals of the Royal College of Surgeons of England [Ann R Coll Surg Engl] 2007 Mar; Vol. 89 (2), pp. W12-3.
Publication Year :
2007

Abstract

Optimal sentinel node identification requires using the combination technique with blue dye and radiocolloid. Allergic reactions to the common blue dyes in use are well recognised. In this report, we present a patient with breast carcinoma who developed a type I hypersensitivity reaction to intradermal injection of technetium-99m labelled nanocolloidal albumin. While reactions to colloids are rare, and in this case minor, operators using this radiopharmaceutical should be prepared for a potential severe anaphylactic reaction.

Details

Language :
English
ISSN :
1478-7083
Volume :
89
Issue :
2
Database :
MEDLINE
Journal :
Annals of the Royal College of Surgeons of England
Publication Type :
Academic Journal
Accession number :
17346392
Full Text :
https://doi.org/10.1308/147870807X160443