Back to Search
Start Over
Assessing heparin dosing in neonates on venoarterial extracorporeal membrane oxygenation.
- Source :
-
ASAIO journal (American Society for Artificial Internal Organs : 1992) [ASAIO J] 2007 Jan-Feb; Vol. 53 (1), pp. 111-4. - Publication Year :
- 2007
-
Abstract
- We studied 12 consecutive neonates placed on venoarterial extracorporeal membrane oxygenation (ECMO) in 2004-2005. Activated clotting times (ACT) and anti-factor Xa levels were measured, and the corresponding heparin drip rate was noted. The mean heparin drip rate was 42.2 +/- 10.9 (SD) U/kg/hour (range 20.0-69.5 U/kg/hour). There were 55 simultaneous ACT and anti-factor Xa samples drawn. The mean ACT was 167 +/- 20 seconds (range 128-227 seconds). There was no correlation between ACT levels and heparin dose (r = 0.21; p = 0.12). The mean anti-factor Xa activities were 0.73 +/- 0.19 U/ml (range 0.1-1.0 U/ml). There was a correlation (r = 0.75; p < 0.0001) between anti-factor Xa and heparin dose. We also examined the effect of day on ECMO on heparin drip rate, ACT, and anti-factor Xa. There was no correlation between day on ECMO and either heparin drip rate (r = 0.21, p = 0.12) or ACT (r = 0.002, p = 0.99). However, there was a positive correlation (r = 0.46, p < 0.0005) between day on ECMO and anti-factor Xa activities. In these neonatal patients on venoarterial ECMO, ACT was not a reliable indicator of heparin effect. Furthermore, the increase in anti-factor Xa levels with time on ECMO suggests that heparin accumulates and/or that anti-thrombin III levels decrease with time on ECMO.
Details
- Language :
- English
- ISSN :
- 1538-943X
- Volume :
- 53
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- ASAIO journal (American Society for Artificial Internal Organs : 1992)
- Publication Type :
- Academic Journal
- Accession number :
- 17237658
- Full Text :
- https://doi.org/10.1097/01.mat.0000247777.65764.b3