Back to Search Start Over

Comparison of two interferon-gamma assays and tuberculin skin test for tracing tuberculosis contacts.

Authors :
Arend SM
Thijsen SF
Leyten EM
Bouwman JJ
Franken WP
Koster BF
Cobelens FG
van Houte AJ
Bossink AW
Source :
American journal of respiratory and critical care medicine [Am J Respir Crit Care Med] 2007 Mar 15; Vol. 175 (6), pp. 618-27. Date of Electronic Publication: 2006 Dec 14.
Publication Year :
2007

Abstract

Background: The tuberculin skin test (TST) has low specificity. QuantiFERON-TB Gold (QFT-G) and T-SPOT.TB are based on interferon (IFN)-gamma responses to Mycobacterium tuberculosis-specific antigens. A novel in-tube format of QFT-G (QFT-GIT) offers logistical advantages.<br />Objective: To compare TST, QFT-GIT, and T-SPOT.TB in bacillus Calmette-Guérin unvaccinated contacts and correlate results with measures of recent exposure.<br />Methods: When a supermarket employee with smear-positive tuberculosis had infected most close contacts, a contact investigation among more than 20,000 customers was performed. We recruited subjects randomly on the day of TST administration (n = 469) and subjects with TST of more than 0 mm on the day of TST reading (n = 316). QFT-GIT and T-SPOT.TB were performed. Demographic data and measures of exposure were collected. TST results were analyzed at a cutoff of 10 or 15 mm. Blood tests were interpreted following the manufacturers' criteria and by varying cutoff levels.<br />Results: Among 785 study participants, TST results were associated with age, whereas positive IFN-gamma responses were significantly associated with cumulative shopping time, most markedly for QFT-GIT. Among participants with a TST of 15 mm or greater, sensitivity of QFT-GIT and T-SPOT.TB was 42.2 and 51.3%, respectively. Interassay agreement was 89.6% (kappa = 0.59). By varying cutoff values, agreement between the IFN-gamma assays was optimal at 93.6% (kappa = 0.71) using a cutoff of 0.20 IU/ml for QFT-GIT and 13 spots for T-SPOT.TB.<br />Conclusions: Blood test results were associated with exposure, whereas the TST was not. A possible lack of sensitivity of IFN-gamma assays in detecting individuals with TST of 15 mm or greater, despite negative bacillus Calmette-Guérin vaccination status, warrants further investigation into alternative cutoff values.

Details

Language :
English
ISSN :
1073-449X
Volume :
175
Issue :
6
Database :
MEDLINE
Journal :
American journal of respiratory and critical care medicine
Publication Type :
Academic Journal
Accession number :
17170386
Full Text :
https://doi.org/10.1164/rccm.200608-1099OC