Back to Search
Start Over
Toxoid flocculation assay by laser light-scattering.
- Source :
-
Journal of immunological methods [J Immunol Methods] 2007 Jan 10; Vol. 318 (1-2), pp. 138-46. Date of Electronic Publication: 2006 Nov 20. - Publication Year :
- 2007
-
Abstract
- Internationally accepted designations of antigen content for toxoid vaccines are provided by the WHO in Lf (limes flocculationis) units, based on the formation of antigen-antibody complexes. The current assay method for Lf determination involves observation of the complexes by eye, making the development of a more objective system highly desirable. Here we report a novel detection system using a laser light-scattering platelet aggregometer. The system was highly reproducible and more objective than the current method. Only three sets of duplicate data were sufficient for statistically significant determination of toxoid Lf by parabolic regression.
- Subjects :
- Diphtheria Antitoxin immunology
Diphtheria Toxoid analysis
Diphtheria Toxoid immunology
Flocculation Tests methods
Particle Size
Regression Analysis
Reproducibility of Results
Tetanus Antitoxin immunology
Tetanus Toxoid analysis
Tetanus Toxoid immunology
Toxoids immunology
Antigen-Antibody Complex analysis
Lasers
Light
Scattering, Radiation
Toxoids analysis
Subjects
Details
- Language :
- English
- ISSN :
- 0022-1759
- Volume :
- 318
- Issue :
- 1-2
- Database :
- MEDLINE
- Journal :
- Journal of immunological methods
- Publication Type :
- Academic Journal
- Accession number :
- 17157306
- Full Text :
- https://doi.org/10.1016/j.jim.2006.10.012