Back to Search Start Over

Dynamic modulation of upper airway function during sleep: a novel single-breath method.

Authors :
Kirkness JP
Schwartz AR
Patil SP
Pichard LE
Marx JJ
Smith PL
Schneider H
Source :
Journal of applied physiology (Bethesda, Md. : 1985) [J Appl Physiol (1985)] 2006 Nov; Vol. 101 (5), pp. 1489-94. Date of Electronic Publication: 2006 Jul 06.
Publication Year :
2006

Abstract

To examine the dynamic modulation of upper airway (UA) function during sleep, we devised a novel approach to measuring the critical pressure (Pcrit) within a single breath in tracheostomized sleep apnea patients. We hypothesized that the UA continuously modulates airflow dynamics during transtracheal insufflation. In this study, we examine tidal pressure-flow relationships throughout the respiratory cycle to compare phasic differences in UA collapsibility between closure and reopening. Five apneic subjects (with tracheostomy) were recruited (2 men, 3 women; 18-50 yr; 20-35 kg/m2; apnea-hypopnea index >20) for this polysomnographic study. Outgoing airflow through the UA (face mask pneumotachograph) and tracheal pressure were recorded during brief transtracheal administration of insufflated airflow via a catheter. Pressure-flow relationships were generated from deflation (approaching Pcrit) and inflation (after Pcrit) of the UA during non-rapid eye movement sleep. During each breath, UA function was described by a pressure-flow relationship that defined the collapsibility (Pcrit) and upstream resistance (Rus). UA characteristics were examined in the presence and absence of complete UA occlusion. We demonstrated that Pcrit and Rus changed dynamically throughout the respiratory cycle. The UA closing pressure (4.4 +/- 2.0 cm H2O) was significantly lower than the opening pressure (10.8 +/- 2.4 cm H2O). Rus was higher for deflation (18.1 +/- 2.4 cm H2O x l(-1) x s) than during inflation (7.5 +/- 1.9 cm H2O x l(-1) x s) of the UA. Preventing occlusion decreases UA pressure-flow loop hysteresis by approximately 4 cm H2O. These findings indicate that UA collapsibility varies dynamically throughout the respiratory cycle and that both local mechanical and neuromuscular factors may be responsible for this dynamic modulation of UA function during sleep.

Details

Language :
English
ISSN :
8750-7587
Volume :
101
Issue :
5
Database :
MEDLINE
Journal :
Journal of applied physiology (Bethesda, Md. : 1985)
Publication Type :
Academic Journal
Accession number :
16825526
Full Text :
https://doi.org/10.1152/japplphysiol.00173.2006