Back to Search Start Over

Novel application of 4D sonography with B-flow imaging and spatio-temporal image correlation (STIC) in the assessment of the anatomy of pulmonary arteries in fetuses with pulmonary atresia and ventricular septal defect.

Authors :
Volpe P
Campobasso G
Stanziano A
De Robertis V
Di Paolo S
Caruso G
Volpe N
Gentile M
Source :
Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology [Ultrasound Obstet Gynecol] 2006 Jul; Vol. 28 (1), pp. 40-6.
Publication Year :
2006

Abstract

Objectives: To assess the reliability of two-dimensional gray-scale (2D) and color Doppler echocardiography in the study of the size and anatomy of the central pulmonary arteries and of the sources of pulmonary blood flow in a case series of fetuses with pulmonary atresia and ventricular septal defect (PA-VSD), and to evaluate whether the use of 4D ultrasound with B-flow imaging and spatio-temporal image correlation (STIC) can improve prenatal diagnostic accuracy.<br />Methods: The study population comprised a group of seven PA-VSD fetuses that had been examined by 2D and color Doppler echocardiography exclusively, and a group of five additional cases identified initially by conventional echocardiography and examined further by 4D ultrasound, for all of which a thorough postnatal or autopsy study of the size and anatomy of the pulmonary arteries and blood supply was available.<br />Results: 2D and color Doppler echocardiography failed to assess the anatomy of the central pulmonary arteries and the source of the pulmonary blood supply in 33% and 25% of the 12 cases, respectively. 4D ultrasound with B-flow imaging and STIC assessed successfully the anatomy of the pulmonary arteries and the source of pulmonary blood supply in all five fetuses examined.<br />Conclusions: The prognosis of PA-VSD is influenced by the anatomy of the pulmonary arteries and the sources of the pulmonary blood supply, and by coexisting extracardiac and genetic anomalies. Our findings, although limited to a small sample size, suggest that 4D echocardiography with B-flow imaging and STIC, unlike 2D ultrasound, can provide thorough visualization of very small vessels and of the arterial blood supply to the lungs of fetuses with PA-VSD. 4D ultrasound may be used in the future to improve and help to detail the diagnosis of other fetal cardiac defects.<br /> (2006 ISUOG. Published by John Wiley & Sons, Ltd.)

Details

Language :
English
ISSN :
0960-7692
Volume :
28
Issue :
1
Database :
MEDLINE
Journal :
Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
Publication Type :
Academic Journal
Accession number :
16795133
Full Text :
https://doi.org/10.1002/uog.2818