Biomechanical studies of the anterior spinal fixators after corpectomy in pigs.
- Source :
-
Journal of the Formosan Medical Association = Taiwan yi zhi [J Formos Med Assoc] 1991 Jan; Vol. 90 (1), pp. 72-80. - Publication Year :
- 1991
-
Abstract
- An unstable corpectomy porcine spinal model was created for the testing of anterior spinal fixators including: Kaneda device (KD), combination of Polster-Brinckmann prosthesis and Zielke implant (PBZ), and a new prototype device (CH). These spinal implants were examined in a one above/one below corpectomy model to determine the relative stiffness of each construct and the deformation of the adjacent discs under loading. The results indicated that the relative torsion and flexion stiffness were higher for the tested spines fixed with KD and CH. However, the relative compression stiffness of the tested spines was the same for all devices. The rigidity of the spinal constructs, which were measured around the corpectomy region showed the same tendency as above. However, the stiffness of CH and KD constructs were significantly higher than that of the PBZ construct under flexion and torsion. The difference in deformation of the upper and lower adjacent discs was not obvious among the intact spine and the spinal constructs with different devices. Clinical relevances: The corpectomy model represents a "worst case" scenario of spinal instability. In many conditions, spinal reconstructive surgery can restore axial compressive, torsional, and flexural rigidity to normal levels. These experimental conclusions apply to acute restoration of stability, rather than to rigidity after long-term cyclical loading. These three anterior fixators extended to only one cephalad level and one caudal level beyond the corpectomy defect. The new prototype device (CH) has a stability to the Kaneda device. The superior mechanical strength and simpler operative procedure of the new device provide for a potential clinical advantage in restoration of unstable spinal conditions.
- Subjects :
- Animals
Biomechanical Phenomena
Bone Cements
External Fixators standards
Fracture Fixation instrumentation
Guinea Pigs
Internal Fixators standards
Joint Instability physiopathology
Joint Instability surgery
Lumbar Vertebrae injuries
Lumbar Vertebrae surgery
Models, Biological
Prostheses and Implants
Spinal Fractures physiopathology
Thoracic Vertebrae injuries
Thoracic Vertebrae surgery
Orthopedic Fixation Devices standards
Spinal Fractures surgery
Spine surgery