[Morphologic and toxicologic evaluation of response to subcutaneous para-osseous implants Medpol-1 and Medpol-2 in rats].
- Source :
-
Annales Universitatis Mariae Curie-Sklodowska. Sectio D: Medicina [Ann Univ Mariae Curie Sklodowska Med] 1990; Vol. 45, pp. 187-94. - Publication Year :
- 1990
-
Abstract
- Cobalt alloys produced in Poland and meant for orthopedic implants were morphologically and toxicologically evaluated. They were implanted subcutaneously in the para-osseous region of rats' heads. The results of the experimental tests strongly suggest the advisability of a clinical research project (study) on the examined cobalt alloys: Medpol-1 and Medpol-2.