Back to Search Start Over

Cadaver validation of intensity-based ultrasound to CT registration.

Authors :
Penney GP
Barratt DC
Chan CS
Slomczykowski M
Carter TJ
Edwards PJ
Hawkes DJ
Source :
Medical image analysis [Med Image Anal] 2006 Jun; Vol. 10 (3), pp. 385-95. Date of Electronic Publication: 2006 Mar 07.
Publication Year :
2006

Abstract

A method is presented for the rigid registration of tracked B-mode ultrasound images to a CT volume of a femur and pelvis. This registration can allow tracked surgical instruments to be aligned with the CT image or an associated preoperative plan. Our method is fully automatic and requires no manual segmentation of either the ultrasound images or the CT volume. The parameter which is directly related to the speed of sound through tissue has also been included in the registration optimisation process. Experiments have been carried out on six cadaveric femurs and three cadaveric pelves. Registration results were compared with a "gold standard" registration acquired using bone implanted fiducial markers. Results show the registration method to be accurate, on average, to 1.6 mm root-mean-square target registration error.

Details

Language :
English
ISSN :
1361-8415
Volume :
10
Issue :
3
Database :
MEDLINE
Journal :
Medical image analysis
Publication Type :
Academic Journal
Accession number :
16520083
Full Text :
https://doi.org/10.1016/j.media.2006.01.003