Back to Search
Start Over
Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis.
- Source :
-
Spine [Spine (Phila Pa 1976)] 2006 Feb 01; Vol. 31 (3), pp. 291-8. - Publication Year :
- 2006
-
Abstract
- Study Design: A retrospective matched cohort study.<br />Objective: To comprehensively compare the 2-year postoperative results of posterior correction and fusion with segmental pedicle screw instrumentation versus with hybrid (proximal hooks and distal pedicle screws) constructs in adolescent idiopathic scoliosis (AIS) treated at a single institution.<br />Summary of Background Data: Despite the reports of satisfactory correction and maintenance of scoliotic curves by pedicle screw instrumentation, there have been no reports on the comprehensive comparison of AIS treatment after segmental pedicle screw instrumentation versus hybrid instrumentation.<br />Materials and Methods: A total of 58 AIS patients that underwent posterior fusion with hybrid instrumentation (29) or pedicle screw (29) instrumentation at a single institution were sorted and matched according to four criteria: similar patient age, fusion levels, identical Lenke curve type, and identical operative methods. Patients were compared at 2-year follow-up according to radiographic changes, operative time, intraoperative blood loss, pulmonary function tests, and SRS-24 outcome scores.<br />Results: The two cohorts were well matched. The preoperative major Cobb angle averaged 62 degrees in the screw group and 60 degrees in the hybrid group. Average major curve correction was 70% in the screw group and 56% in the hybrid group (P = 0.001). At 2-year follow-up, major curve correction was 65% and 46%, respectively (P < 0.001). At 2-year follow-up, thoracic sagittal Cobb angle changes between T5 and T12 were 9.0 degrees decrease in the screw group and 2.4 degrees decrease in the hybrid group compared with preoperative (P = 0.024). There were no differences in the lowest instrumented vertebra below the lower end vertebra (P = 0.56), operative time (P = 0.14), and average estimated blood loss (P = 0.54). Two years following surgery, the screw group demonstrated improved percent predicted pulmonary function values compared with that of the hybrid group (FVC; 81% --> 81% in screw group vs. 85% --> 79% in hybrid group P = 0.08, FEV1; 73% --> 79% in screw group vs. 79% --> 75% in hybrid group, P = 0.006). Postoperative total SRS-24 scores were similar in both groups (hybrid group: 99 vs. screw group: 95) (P = 0.19). There were no neurologic complications related to hybrid or pedicle screw instrumentation.<br />Conclusion: Pedicle screw instrumentation offers a significantly better major curve correction and postoperative pulmonary function values without neurologic problems compared with hybrid constructs. Both instrumentation methods offer similar junctional change, lowest instrumented vertebra, operative time, and postoperative SRS-24 outcome scores in the operative treatment of AIS.
- Subjects :
- Adolescent
Adult
Child
Cohort Studies
Female
Humans
Lumbar Vertebrae diagnostic imaging
Lumbar Vertebrae surgery
Male
Prospective Studies
Radiography
Retrospective Studies
Scoliosis diagnostic imaging
Thoracic Vertebrae diagnostic imaging
Thoracic Vertebrae surgery
Bone Screws
Scoliosis surgery
Spinal Fusion instrumentation
Spinal Fusion methods
Subjects
Details
- Language :
- English
- ISSN :
- 1528-1159
- Volume :
- 31
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Spine
- Publication Type :
- Academic Journal
- Accession number :
- 16449901
- Full Text :
- https://doi.org/10.1097/01.brs.0000197865.20803.d4