Back to Search
Start Over
Hearing results with the titanium ossicular replacement prostheses.
- Source :
-
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery [Eur Arch Otorhinolaryngol] 2006 Apr; Vol. 263 (4), pp. 347-54. Date of Electronic Publication: 2005 Dec 03. - Publication Year :
- 2006
-
Abstract
- The purpose was to study the hearing results in patients receiving a Kurz titanium Bell partial ossicular replacement prosthesis (PORP) or an Aerial total ossicular replacement prosthesis (TORP). The study was a retrospective chart review in a tertiary otologic referral center. A computerized otologic database was used to identify 111 patients implanted with either a PORP or TORP prosthesis. Audiograms were reviewed and air-bone gaps were calculated for each patient. The improvement of the average air-bone gap (ABG) was 10.2 and 12.7 dB at 3 and 20 months after ossiculoplasty, respectively. Sixty-six percent of patients (73/111) had a postoperative air-bone gap of 20 dB or less. The ABG for the titanium PORP prosthesis was 14.3+/-9.7 dB, compared with 25.2+/-13.7 dB for the TORP prosthesis (P <0.05). The ABG to within 20 dB or less was obtained in the PORP group in 77% of the cases, versus 52% of the cases in the TORP group (P <0.05). Two extrusions of the prostheses were observed at 17 and 20 months after surgery (1.8%). Revision procedures for functional failure were carried out in 20 patients (18%). The rate of sensorineural hearing loss was 3.6%. The major factors influencing good audiometric results were the surgical procedure preserving the external auditory canal and the presence of the stapes. The best hearing results were achieved when a PORP was used in an intact canal wall (ICW) procedure, and the worst hearing results were achieved when a TORP was used in a canal wall down (CWD) procedure. The titanium Kurz prosthesis has been an effective implant at our institution for ossicular reconstruction.
Details
- Language :
- English
- ISSN :
- 0937-4477
- Volume :
- 263
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 16328409
- Full Text :
- https://doi.org/10.1007/s00405-005-1002-6