Back to Search
Start Over
Does position of syndesmotic screw affect functional and radiological outcome in ankle fractures?
- Source :
-
Injury [Injury] 2005 Sep; Vol. 36 (9), pp. 1121-4. - Publication Year :
- 2005
-
Abstract
- The optimum level of syndesmotic screw used in ankle fractures with a tibiofibular diastasis is not clear in the literature. In a retrospective cohort study, we evaluated the clinical and radiological outcomes in two groups of patients-those who had a syndesmotic screw placed through the syndesmosis itself (transsyndesmotic, 17 patients) and those who had a syndesmotic screw placed just above the syndesmosis (suprasyndesmotic, 19 patients). The study suggests that the two groups do not differ significantly in terms of clinical and radiological outcomes.
- Subjects :
- Ankle Injuries diagnostic imaging
Ankle Injuries physiopathology
Ankle Joint physiopathology
Fibula physiopathology
Humans
Joint Dislocations diagnostic imaging
Joint Dislocations physiopathology
Joint Dislocations surgery
Pain Measurement
Radiography
Range of Motion, Articular
Retrospective Studies
Synostosis diagnostic imaging
Synostosis physiopathology
Synostosis surgery
Tibia physiopathology
Treatment Outcome
Ankle Injuries surgery
Bone Screws
Fracture Fixation, Internal methods
Subjects
Details
- Language :
- English
- ISSN :
- 0020-1383
- Volume :
- 36
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Injury
- Publication Type :
- Academic Journal
- Accession number :
- 16051235
- Full Text :
- https://doi.org/10.1016/j.injury.2005.01.014