Back to Search Start Over

Development and optimization of a method for the analysis of Brazilein by HPLC with electrochemical detection.

Authors :
Yan X
Wang W
Xing D
Zhao Y
Du L
Source :
Journal of chromatography. A [J Chromatogr A] 2005 Jun 03; Vol. 1077 (1), pp. 44-8.
Publication Year :
2005

Abstract

The aim of this study was to establish an easy and accurate method for the determination of Brazilein in plant samples due to its potential pharmacological activities. High-performance liquid chromatography (HPLC) with electrochemical detection (ED) was used for the assay of Brazilein in this study for the first time. Crucial influence parameters including concentration of dodecane-1-sulfonic acid sodium salt (DSASS), inorganic modifier, tetrabutyl-ammonium hydroxide solution (TBAOH), and applied potential of proposed method were investigated. The proposed method is simple, rapid (analysis time: approximately 10 min), sensitive [(detection limit: 0.6 ng per injection (20 microl) at a signal-noise ratio 3:1)], highly selective and precise (intra- and inter-day precisions were within 5%, n = 7). The calibration graph of Brazilein was linear in the range 0.6-150 ng per injection 20 microl. Recovery of Brazilein was over 92% by standard addition method.

Details

Language :
English
ISSN :
0021-9673
Volume :
1077
Issue :
1
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
15988985
Full Text :
https://doi.org/10.1016/j.chroma.2005.04.050