Back to Search
Start Over
Cefoxitin disk diffusion screen for confirmation of oxacillin-resistant Staphylococcus aureus isolates and utility in the clinical laboratory.
- Source :
-
Diagnostic microbiology and infectious disease [Diagn Microbiol Infect Dis] 2005 Jan; Vol. 51 (1), pp. 69-71. - Publication Year :
- 2005
-
Abstract
- One hundred Vitek-2 identified oxacillin resistant S. aureus (ORSA) isolates were tested by oxacillin screen-plate (OXA-plate) and cefoxitin disk (FOX-disk) for confirmation of oxacillin resistance. Ninety-five of 100 confirmed oxacillin resistant by both, 3 of 5 were oxacillin susceptible by both and mecA negative, and 2 of 5 were oxacillin susceptible by OXA-plate, resistant by FOX-disk and mecA positive. The FOX-disk out-performed the OXA-plate for ORSA confirmation and can be performed using standard laboratory techniques.
Details
- Language :
- English
- ISSN :
- 0732-8893
- Volume :
- 51
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Diagnostic microbiology and infectious disease
- Publication Type :
- Academic Journal
- Accession number :
- 15629232
- Full Text :
- https://doi.org/10.1016/j.diagmicrobio.2004.09.003