Cefoxitin disk diffusion screen for confirmation of oxacillin-resistant Staphylococcus aureus isolates and utility in the clinical laboratory.

Authors :
Sharp SE
Warren JA
Thomson RB Jr
Source :
Diagnostic microbiology and infectious disease [Diagn Microbiol Infect Dis] 2005 Jan; Vol. 51 (1), pp. 69-71.
Publication Year :
2005

Abstract

One hundred Vitek-2 identified oxacillin resistant S. aureus (ORSA) isolates were tested by oxacillin screen-plate (OXA-plate) and cefoxitin disk (FOX-disk) for confirmation of oxacillin resistance. Ninety-five of 100 confirmed oxacillin resistant by both, 3 of 5 were oxacillin susceptible by both and mecA negative, and 2 of 5 were oxacillin susceptible by OXA-plate, resistant by FOX-disk and mecA positive. The FOX-disk out-performed the OXA-plate for ORSA confirmation and can be performed using standard laboratory techniques.