Back to Search
Start Over
Microleakage of new crown and fixed partial denture luting agents.
- Source :
-
The Journal of prosthetic dentistry [J Prosthet Dent] 1992 Feb; Vol. 67 (2), pp. 156-61. - Publication Year :
- 1992
-
Abstract
- This study measured the in vitro microleakage of conventional and new FPD luting agents. Standardized preparations were made on 42 freshly extracted premolars. Facial and lingual chamfer margins were placed in enamel, mesial and distal in dentin and cementum, and castings were made in Rexillium III alloy and were then cemented with a standardized technique. Six groups of seven samples were tested, (1) polycarboxylate, (2) zinc phosphate, (3) glass ionomer, (4) Den-Mat Thin Film cement, (5) Panavia Ex, and (6) Den-Mat Thin Film cement with Tenure. The ranking of groups for stain ingress was from the greatest (1) to the least (6). A one-way analysis of variance and Tukey-Student range analysis revealed significantly similar groups, p less than 0.05:(1,2,3,4) (5,6).
- Subjects :
- Cementation
Coloring Agents
Composite Resins chemistry
Dental Bonding
Dental Enamel anatomy & histology
Dentin anatomy & histology
Denture Design
Humans
Magnesium Oxide chemistry
Materials Testing
Phosphates chemistry
Polycarboxylate Cement chemistry
Surface Properties
Zinc Oxide chemistry
Zinc Phosphate Cement chemistry
Adhesives chemistry
Crowns
Dental Cements chemistry
Dental Leakage
Denture, Partial, Fixed
Resin Cements
Subjects
Details
- Language :
- English
- ISSN :
- 0022-3913
- Volume :
- 67
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- The Journal of prosthetic dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 1538320
- Full Text :
- https://doi.org/10.1016/0022-3913(92)90447-i