Back to Search Start Over

Successful reduction of in-stent restenosis in long lesions using beta-radiation--subanalysis from the RENO registry.

Authors :
Baumgart D
Bonan R
Naber C
Serruys P
Colombo A
Silber S
Eeckhout E
Urban P
Source :
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2004 Mar 01; Vol. 58 (3), pp. 817-27.
Publication Year :
2004

Abstract

Purpose: Long lesions remain a challenging task in interventional cardiology, with a high propensity of restenosis, especially within the stented segment. Although intracoronary gamma-radiation has been proved to reduce diffuse in-stent restenosis in long lesions, such an effect remains to be determined using beta-radiation.<br />Methods and Materials: Of 1098 consecutive patients at 46 European centers treated with localized beta-radiation ((90)Sr, Novoste Beta-Cath System), 139 patients (mean age 61.5 +/- 10.7 years, 84% male, 22% with diabetes mellitus) with lesions treated using a >40-mm source length underwent radiation using a single 60-mm source train (34%) or a stepping/pullback procedure with a 30-mm (12%) or 40-mm (87%) source length after conventional interventional procedures. The mean lesion length was 35.3 +/- 17.9 mm.<br />Results: Technical success was achieved in 96% of cases. Geographic miss was noted in 9 patients (6.5%). The reference (placebo) group was obtained from the Washington Hospital Center for In-Stent Restenosis Trial (WRIST) and the WRIST Trial for long lesions (LONG WRIST) studies by selecting the cases (94 patients) that required a dummy source length >/=13 seeds (or >51 mm in length). Statistically significant improvement was noted in late angiographic restenosis (34.7% vs. 76.5%, p <0.0001), target vessel revascularization (14.9% vs. 60.6), and major adverse cardiac events (i.e., death, myocardial infarction, or total vessel revascularization) (17.9% vs. 64.9%, p <0.0001) at 6 months in reference to the nonradiation group.<br />Conclusion: This subanalysis from the Radiation in Europe with Novoste study confirms the safety and efficacy of beta-radiation combined with conventional interventional procedures in patients with diffuse, long, in-stent restenosis

Details

Language :
English
ISSN :
0360-3016
Volume :
58
Issue :
3
Database :
MEDLINE
Journal :
International journal of radiation oncology, biology, physics
Publication Type :
Academic Journal
Accession number :
14967439
Full Text :
https://doi.org/10.1016/S0360-3016(03)01615-8