Back to Search Start Over

The new materials processing beamline at the SRS Daresbury, MPW6.2.

Authors :
Cernik RJ
Barnes P
Bushnell-Wye G
Dent AJ
Diakun GP
Flaherty JV
Greaves GN
Heeley EL
Helsby W
Jacques SD
Kay J
Rayment T
Ryan A
Tang CC
Terrill NJ
Source :
Journal of synchrotron radiation [J Synchrotron Radiat] 2004 Mar 01; Vol. 11 (Pt 2), pp. 163-70. Date of Electronic Publication: 2004 Feb 12.
Publication Year :
2004

Abstract

A new beamline (MPW6.2) has been designed and built for the study of materials during processing where three synchrotron techniques, SAXS, WAXS and XAS, are available simultaneously. It has been demonstrated that Rietveld refinable data can be collected from silicon SRM 640b over a 60 degrees range in a time scale of 1 s. The data have been refined to a chi(2) of 2.4, the peaks fitting best to a Pearson VII function or with fundamental parameters. The peak halfwidths have been found to be approximately constant at 0.06 degrees over a 120 degrees angular range indicating that the instrumental resolution function has matched its design specification. A quantitative comparison of data sets collected on the same isotactic polypropylene system on MPW6.2 and DUBBLE at the ESRF shows a 17% improvement in angular resolution and a 1.8 improvement in peak-to-background ratio with the RAPID2 system; the ESRF data vary more smoothly across detector channels. The time-dependent wide-angle XRD was tested by comparing a hydration reaction of gypsum-bassanite-anhydrite with energy-dispersive data collected on the same system on the same time scale. Three sample data sets from the reaction were selected for analysis and gave an average chi(2) of 3.8. The Rietveld-refined lattice parameters are a good match with published values and the corresponding errors show a mean value of 3.3 x 10(-4). The data have also been analysed by the Pawley decomposition phase-modelling technique demonstrating the ability of the station to quickly and accurately identify new phases. The combined SAXS/WAXS capability of the station was tested with the crystallization and spinodal decomposition of a very dilute polymer system. Our measurements show that the crystallization of a high-density co-polymer (E76B38) as low as 0.5% by weight can be observed in solution in hexane. The WAXS and SAXS data sets were collected on the same time scale. The SAXS detector was calibrated using a collagen sample that gave 30 orders of diffraction in 1 s of data collection. The combined XRD and XAS measurement capability of the station was tested by observing the collapse and re-crystallization of zinc-exchanged zeolite A (zeolite Zn/Na-A). Previous studies of this material on station 9.3 at the SRS were compared with those from the new station. A time improvement of 38 was observed with better quality counting statistics. The improved angular resolution from the WAXS detector enabled new peaks to be identified.

Details

Language :
English
ISSN :
0909-0495
Volume :
11
Issue :
Pt 2
Database :
MEDLINE
Journal :
Journal of synchrotron radiation
Publication Type :
Academic Journal
Accession number :
14960781
Full Text :
https://doi.org/10.1107/S0909049503027870