Back to Search Start Over

High-performance liquid chromatographic determination of nicotinamide and its metabolites in human and murine plasma and urine.

Authors :
Stratford MR
Dennis MF
Source :
Journal of chromatography [J Chromatogr] 1992 Nov 06; Vol. 582 (1-2), pp. 145-51.
Publication Year :
1992

Abstract

A high-performance liquid chromatographic method is described which enables the determination of nicotinamide and eight of its possible metabolites in human and murine plasma and urine, using ion-pairing on a base-deactivated reversed-phase column. Calibration curves were linear up to 2 mumol/ml for nicotinamide and 200 nmol/ml for the metabolites; both the intra- and inter-assay relative standard deviations ranged between 1 and 8%. In murine plasma, the N-oxide was the major nicotinamide metabolite, but in man, formation of 1-methylnicotinamide and the 2- and 4-pyridones was also significant. In urine, nicotinuric acid was seen in the mouse, but no nicotinic acid metabolites were seen in man.

Details

Language :
English
Volume :
582
Issue :
1-2
Database :
MEDLINE
Journal :
Journal of chromatography
Publication Type :
Academic Journal
Accession number :
1491034
Full Text :