Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.

Authors :
Lipke CS
Kühl HP
Nowak B
Kaiser HJ
Reinartz P
Koch KC
Buell U
Schaefer WM
Source :
European journal of nuclear medicine and molecular imaging [Eur J Nucl Med Mol Imaging] 2004 Apr; Vol. 31 (4), pp. 482-90. Date of Electronic Publication: 2004 Jan 14.
Publication Year :
2004

Abstract

The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography ((99m)Tc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated (99m)Tc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest. LV EDV, ESV and LVEF were calculated from gated (99m)Tc-MIBI SPET using 4D-MSPECT and QGS. On the same day, cMRI (20 gates/cardiac cycle) was performed, with LV EDV, ESV and LVEF calculated using Simpson's rule. Both algorithms worked with all data sets. Correlation between the results of gated (99m)Tc-MIBI SPET and cMRI was high for EDV [ R=0.89 (4D-MSPECT), R=0.92 (QGS)], ESV [ R=0.96 (4D-MSPECT), R=0.96 (QGS)] and LVEF [ R=0.89 (4D-MSPECT), R=0.90 (QGS)]. In contrast to ESV, EDV was significantly underestimated by 4D-MSPECT and QGS compared to cMRI [130+/-45 ml (4D-MSPECT), 122+/-41 ml (QGS), 139+/-36 ml (cMRI)]. For LVEF, 4D-MSPECT and cMRI revealed no significant differences, whereas QGS yielded significantly lower values than cMRI [57.5%+/-13.7% (4D-MSPECT), 52.2%+/-12.4% (QGS), 60.0%+/-15.8% (cMRI)]. In conclusion, agreement between gated (99m)Tc-MIBI SPET and cMRI is good across a wide range of clinically relevant LV volume and LVEF values assessed by 4D-MSPECT and QGS. However, algorithm-varying underestimation of LVEF should be accounted for in the clinical context and limits interchangeable use of software.

Details

Language :
English
ISSN :
1619-7070
Volume :
31
Issue :
4
Database :
MEDLINE
Journal :
European journal of nuclear medicine and molecular imaging
Publication Type :
Academic Journal
Accession number :
14722679
Full Text :
https://doi.org/10.1007/s00259-003-1411-y