Back to Search Start Over

Sonographic evaluation of the anterior liver surface in chronic liver diseases using a 7.5-MHz annular-array transducer: correlation with laparoscopic and histopathologic findings.

Authors :
Nagata N
Miyachi H
Nakano A
Nanri K
Kobayashi H
Matsuzaki S
Source :
Journal of clinical ultrasound : JCU [J Clin Ultrasound] 2003 Oct; Vol. 31 (8), pp. 393-400.
Publication Year :
2003

Abstract

Purpose: We studied the sonographic appearance of the anterior liver surface using an ultrasound scanner equipped with a 7.5-MHz annular-array transducer to determine the accuracy of this imaging modality in monitoring the course of chronic liver diseases.<br />Methods: We prospectively evaluated patterns of the liver surface in the sonograms of 77 consecutive patients with chronic liver diseases who had undergone sonographic examination with a 7.5-MHz annular-array transducer and a 3.75-MHz convex-array transducer over a 2-year period and compared these findings with those of laparoscopy (using previously described categories) and histopathology.<br />Results: Histopathologically confirmed disease prevalences for inactive chronic hepatitis, active chronic hepatitis, liver cirrhosis, and others were 10% (8/77), 56% (43/77), 29% (22/77), and 5% (4/77), respectively. The sonographic appearance of the liver surface with the 3.75-MHz transducer was classified as either a regular or an irregular pattern. The regular pattern corresponded to 69% (34/50) of the cases in laparoscopic category 200 or 300 and the irregular pattern with 85% (23/27) of the cases in category 400 or 500. The sonographic appearance of the liver surface with the 7.5-MHz transducer was classified as regular, unevenly irregular, diffusely irregular, or nodular. These 4 patterns detected 75% (24/32), 78% (14/18), 52% (12/23), and 75% (3/4) of the cases of laparoscopic categories 200, 300, 400, and 500, respectively. In a comparison of the sonographic patterns of the liver surface with the differential histopathologic findings, the regular sonographic pattern corresponded to 88% (7/8) of the cases of inactive chronic hepatitis, the unevenly irregular pattern with 35% (15/43) of the cases of active chronic hepatitis, and the diffusely irregular and nodular patterns (considered as 1 group) with 68% (15/22) of the cases of liver cirrhosis.<br />Conclusions: Our results suggest that sonographic evaluation of the liver surface with a 7.5-MHz annular-array transducer using this classification provides detailed information on the evolution of chronic liver diseases that correlates with the laparoscopic and histopathologic findings and thus is a useful noninvasive method for monitoring the disease course to cirrhosis.<br /> (Copyright 2003 Wiley Periodicals, Inc. J Clin Ultrasound 31: 393-400, 2003)

Details

Language :
English
ISSN :
0091-2751
Volume :
31
Issue :
8
Database :
MEDLINE
Journal :
Journal of clinical ultrasound : JCU
Publication Type :
Academic Journal
Accession number :
14528436
Full Text :
https://doi.org/10.1002/jcu.10195