Back to Search Start Over

[Pollution by nitrous dioxide during diagnostic laparoscopy interventions].

Authors :
Meneghetti P
Scapellato ML
Marcuzzo G
Priante E
Bartolucci GB
Source :
Giornale italiano di medicina del lavoro [G Ital Med Lav] 1992 Jan-Nov; Vol. 14 (1-6), pp. 59-61.
Publication Year :
1992

Abstract

Here we have outlined the data relative to an environmental survey carried out in a laparoscopy clinic at the hospital of Padua, to determine the environmental concentration of nitrous dioxide (N2O) used for intra-abdominal inflation during diagnostic laparoscopy interventions. The data obtained have revealed cases of considerable N2O environmental pollution. This above all, due to spontaneous loss of gas during the intervention and to the lack of adequate ventilation systems.