Back to Search Start Over

Hepatic MR imaging with ferumoxides: multicenter study of safety and effectiveness of direct injection protocol.

Authors :
Bluemke DA
Weber TM
Rubin D
de Lange EE
Semelka R
Redvanly RD
Chezmar J
Outwater E
Carlos R
Saini S
Holland GA
Mammone JF
Brown JJ
Milestone B
Javitt MC
Jacobs P
Source :
Radiology [Radiology] 2003 Aug; Vol. 228 (2), pp. 457-64.
Publication Year :
2003

Abstract

Purpose: To compare the safety and effectiveness of an undiluted direct injection of ferumoxides with those of a diluted slow infusion of ferumoxides during 30 minutes in patients with known liver lesions or in those suspected of having them.<br />Materials and Methods: Two hundred thirty-three patients at 16 institutions were randomized to receive either an undiluted direct injection of 0.56 mg of iron per kilogram of body weight of ferumoxides administered during 2 minutes (2 mL/min) or a diluted slow infusion administered during 30 minutes. Safety was assessed with monitoring for adverse events and laboratory tests. For sensitivity, specificity, and accuracy analysis, two independent blinded observers identified and classified lesions as benign or malignant with precontrast images and with pre- and postcontrast images combined.<br />Results: There was no statistically significant difference in adverse events in the group with direct injection compared with those in the group with infusion (21 [18%] of 114 patients vs 19 [17%] of 112 patients, respectively). No serious adverse events were observed. The most common adverse events in the group with direct injection versus the group with infusion were headache (five [4%] of 114 vs three [3%] of 112, respectively) and back pain (five [4%] of 114 vs three [3%] of 112, respectively). Overall, in 68 (62%) of 109 patients with direct injection and 71 (66%) of 108 patients with infusion, additional magnetic resonance (MR) imaging information was obtained after ferumoxides administration (P =.67). Sensitivity, specificity, and accuracy for the diagnosis of malignancy were significantly improved by adding images obtained after ferumoxides administration to the images obtained before contrast agent administration (P <.05 for all comparisons).<br />Conclusion: Direct injection of ferumoxides has safety and effectiveness profiles similar to those of slow infusion of the agent. Further findings indicate that the addition of ferumoxides increases the sensitivity and specificity of hepatic MR evaluation when compared with unenhanced MR imaging.<br /> (Copyright RSNA, 2003.)

Details

Language :
English
ISSN :
0033-8419
Volume :
228
Issue :
2
Database :
MEDLINE
Journal :
Radiology
Publication Type :
Academic Journal
Accession number :
12893904
Full Text :
https://doi.org/10.1148/radiol.2282012061