Back to Search
Start Over
Treatment of domestic sewage in a two-step anaerobic filter/anaerobic hybrid system at low temperature.
- Source :
-
Water research [Water Res] 2002 May; Vol. 36 (9), pp. 2225-32. - Publication Year :
- 2002
-
Abstract
- The treatment of domestic sewage at low temperature of 13 degrees C was investigated in a two-step system consisting of an anaerobic filter (AF) +an anaerobic hybrid (AH) reactor operated at different hydraulic retention times (HRTs). The AF reactor was efficient in the removal of suspended COD, viz. 81%, 58% and 57% at an HRT of, respectively, 4, 2 and 3 h. For optimisation of the removal of suspended COD and dissolved COD, an HRT of 4 + 4 h is required for the AF + AH system. For additional optimisation of colloidal COD removal, the AH reactor needs an HRT of 8 h. The AF + AH system operated at an HRT of 4 + 8 h at 13 degrees C provided a high removal efficiency for all COD fractions. The achieved total COD removal was as high as 71% which is similar to values found in tropical areas. Moreover, 60% of the removed COD was converted to methane.
Details
- Language :
- English
- ISSN :
- 0043-1354
- Volume :
- 36
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Water research
- Publication Type :
- Academic Journal
- Accession number :
- 12108715
- Full Text :
- https://doi.org/10.1016/s0043-1354(01)00438-9