Back to Search
Start Over
Evaluation of accelerator mass spectrometry in a human mass balance and pharmacokinetic study-experience with 14C-labeled (R)-6-[amino(4- chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl]-4-(3-chlorophenyl)-1- methyl-2(1H)-quinolinone (R115777), a farnesyl transferase inhibitor.
- Source :
-
Drug metabolism and disposition: the biological fate of chemicals [Drug Metab Dispos] 2002 Jul; Vol. 30 (7), pp. 823-30. - Publication Year :
- 2002
-
Abstract
- Accelerator mass spectrometry (AMS) has been used in a human mass balance and metabolism study to analyze samples taken from four healthy male adult subjects administered nanoCurie doses of the farnesyl transferase inhibitor 14C-labeled (R)-6-[amino(4-chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl]-4-(3-chlorophenyl)-1-methyl-2(1H)-quinolinone ([14C]R115777). Plasma, urine, and feces samples were collected at fixed timepoints after oral administration of 50 mg [14C]R115777 (25.4 Bq/mg or 687 pCi/mg i.e., equivalent to 76.257 x 10(3) dpm) per subject. AMS analysis showed that drug-related (14)C was present in the plasma samples with C(max) values ranging from 1.6055 to 2.9074 dpm/ml (1.0525-1.9047 microg/ml) at t(max) = 2 to 3 h. The C(max) values for acetonitrile extracts of plasma samples ranged from 0.3724 to 0.7490 dpm/ml in the four male subjects. Drug-related 14C was eliminated from the body both in the urine and the feces, with a mean total recovery of 79.8 +/- 12.9% in the feces and 13.7 +/- 6.2% in the urine. The majority of drug-related radioactivity in urine and feces was excreted within the first 48 h. High-performance liquid chromatography (HPLC)-AMS profiles were generated from radioactive parent drug plus metabolites from pooled diluted urine, plasma, and methanolic feces extracts and matched to retention times of synthetic reference substances, postulated as metabolites. All HPLC separations used no more than 5 dpm injected on-column. The radioactive metabolite profiles obtained compared well with those obtained using liquid chromatography/tandem mass spectometry. This study demonstrates the use of AMS in a human phase I study in which the administered radioactive dose was at least 1000-fold lower than that used for conventional radioactive studies.
- Subjects :
- Adult
Chromatography, High Pressure Liquid methods
Enzyme Inhibitors chemistry
Farnesyltranstransferase
Humans
Male
Mass Spectrometry methods
Particle Accelerators instrumentation
Quinolones chemistry
Alkyl and Aryl Transferases antagonists & inhibitors
Enzyme Inhibitors analysis
Enzyme Inhibitors pharmacokinetics
Quinolones analysis
Quinolones pharmacokinetics
Subjects
Details
- Language :
- English
- ISSN :
- 0090-9556
- Volume :
- 30
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Drug metabolism and disposition: the biological fate of chemicals
- Publication Type :
- Academic Journal
- Accession number :
- 12065441
- Full Text :
- https://doi.org/10.1124/dmd.30.7.823