Back to Search
Start Over
Determination of 6-mercaptopurine and azathioprine in plasma by high-performance liquid chromatography.
- Source :
-
Journal of chromatography [J Chromatogr] 1979 Jul 21; Vol. 163 (3), pp. 281-8. - Publication Year :
- 1979
-
Abstract
- Using 1-ml plasma samples, levels of 6-mercaptopurine (6MP) as low as 5 ng/ml and azathioprine (AZA) as low as 40 ng/ml can be detected using a high-performance liquid chromatography reversed-phase column procedure following extraction. Both compounds were stable in frozen plasma for seven weeks. AZA stability in blood was temperature dependent; the half-lives of AZA breakdown to 6MP at 37 degrees were 28 and 46 min in blood drawn from two rhesus monkeys. Plasma levels of 6MP were measured in a rhesus monkey following 6MP (1.47 mg/kg) and AZA (3 mg/kg) intravenous administration. 6MP levels were also measured in three renal transplant patients on daily 50- and 100-mg AZA doses. Peak levels (45-75 ng/ml) were reached within an hour and 6MP levels were detected for up to 7 h.
Details
- Language :
- English
- Volume :
- 163
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Journal of chromatography
- Publication Type :
- Academic Journal
- Accession number :
- 120373
- Full Text :
- https://doi.org/10.1016/s0378-4347(00)81415-2